Линия коагуляции и промывки DMF | Кожа мокрого процесса
Многоступенчатый комплекс коагуляции DMF/воды и противоточной промывки с контролируемой циркуляцией и интерфейсами регенерации.
Water Circulation Flow
Wash water circulation: 10.0 to 60.0 m³/hour
Circulation Pressure
0.2 to 0.4 MPa (Circulation and spray piping)
Tank Array
Multi-tank array: 6 x 3,500 L (Stainless steel 304 sealed)
Line Dimensions
36,000 mm x 2,800 mm x 2,200 mm
Multi-Stage Countercurrent Washing for Wet Synthetic Leather
Многоступенчатый комплекс коагуляции DMF/воды и противоточной промывки с контролируемой циркуляцией и интерфейсами регенерации.
Multistage DMF/water coagulation and countercurrent washing are configured with circulation, concentration monitoring and web-handling interfaces. Distillation, extraction, wastewater treatment and upstream coating are separately identified in the supply scope.
Effluent concentration and a reactive-resin mixing ratio are different quantities. Optical concentration monitoring requires calibration for the actual composition and temperature. Water consumption, solvent recovery and energy use are evaluated within a defined process boundary.
Концептуальная иллюстрация: Сгенерированная иллюстрация для обсуждения процесса; не фотография указанной машины, объекта заказчика или реализованного проекта.

Поток материалов и принцип работы
Set the Coagulation Process
Configure the DMF/water tanks, web path and solution conditions for the selected upstream coated substrate.
Run Countercurrent Washing
Coordinate water replenishment, circulation and web residence through the selected stages.
Monitor and Transfer Effluent
Use calibrated concentration measurements to coordinate replenishment and the separately defined recovery interface.
Inspect and Handle the Web
Check the washed substrate and transfer it to the agreed downstream process; verify solvent and wastewater results within the defined plant scope.
Нужно коммерческое предложение на это оборудование?
Запросить предложениеМодель и технические параметры
Reference data describe the selected coagulation, washing, circulation and concentration-monitoring package. Recovery purity, water use, steam demand and emission performance require the corresponding process balance and acceptance measurements.
| Технический параметр | HF-WET200-REC |
|---|---|
| Компоненты | Multi-Stage Fluid System (Water + DMF Solvent Recycle) |
| Диапазон производительности | Wash water circulation: 10.0 to 60.0 m³/hour |
| Электропитание | 380 В, 3 фазы, 50 Гц (по заказу 440 В/480 В 60 Гц) |
| Рабочее давление | 0.2 to 0.4 MPa (Circulation and spray piping) |
| Объём бака / бункера | Multi-tank array: 6 x 3,500 L (Stainless steel 304 sealed) |
| Масса | 14,200 kg (Complete 6-stage washing tanks and piping array) |
| Габариты (Д×Ш×В) | 36,000 mm x 2,800 mm x 2,200 mm |
| Target effluent DMF concentration | Effluent DMF Concentration 18% to 22% (Target steady state); supplied configuration reference, see review point |
| Refractometer reference; calibration required | ±0.5% Brix / Concentration (Digital optical refractometer); supplied configuration reference, see review point |
Ключевые особенности оборудования
Configured coagulation/washing tanks, circulation pumps, fluid monitoring and web-handling interfaces. Distillation, extraction, wastewater treatment and upstream coating scope are separately agreed.
Recovery-System Interfaces
Coordinate washing effluent concentration and transfer with the separately sized solvent-recovery plant.
Countercurrent Washing
The staged arrangement directs cleaner water toward the final washing zone. Actual water demand follows web loading, residual-solvent targets and the selected operating balance.
Calibrated Concentration Monitoring
Calibrate the optical instrument for the DMF/water composition and temperature before using its reading to control replenishment.
Configured Vapor Extraction
Coordinate enclosed extraction with the site recovery system and installed-process measurements.
Обсудите конфигурацию вашего оборудования
Сообщите о вашей продукции, материалах, оснастке и требованиях к производству, чтобы мы могли рассмотреть оборудование и интерфейсы для вашего проекта.
Часто задаваемые вопросы
What is included in the washing package?
Does a Brix reading directly give DMF concentration?
Can an existing line be retrofitted?
How are water and steam savings verified?
Готовы обсудить ваш проект?
Свяжитесь с нашей командой