Máquina de espumado de PU de alta presión con ciclopentano | Espuma rígida de aislamiento
Cyclopentane high-pressure PU metering and impingement mixing with 150–500 g/s combined output at 1:1, twin 280 L tanks and PLC-controlled circulation.
Caudal de descarga
150–500 g/s combined output at 1:1; equivalent to 9–30 kg/min
Relación de mezcla
1:2–2:1 adjustable; confirm component order and calibration for the formulation
Shot Repeatability
≤±1% for injection duration greater than 1 s
Control de temperatura
22°C stated summer control point, ±2°C deviation; recipe setpoint agreed with material supplier
Two-Component High-Pressure Processing
Cyclopentane high-pressure PU metering and impingement mixing with 150–500 g/s combined output at 1:1, twin 280 L tanks and PLC-controlled circulation.
Haifeng supplies this two-component high-pressure PU foaming configuration for cyclopentane-based material processing. Independent polyol and isocyanate metering circuits feed a hydraulically operated, mechanically self-cleaning impingement mixing head. The equipment package includes material tanks, metering pumps, a hydraulic unit, component circulation, temperature conditioning and PLC/HMI controls.
The JHG-AFL-30 configuration specifies a combined injection output of 150–500 g/s at a 1:1 component ratio, equivalent to 9–30 kg/min. Injection pressure is adjustable from 10 to 20 MPa, and the stated component ratio range is 1:2–2:1. Final sizing uses the selected formulation, shot weight and cycle requirements.
A gas-detection unit, audible alarm and extraction interface are included in the technical scope. Detector settings, ventilation requirements, interlock actions and applicable component documentation are defined with the final project configuration.

Material Flow and Injection Cycle
Condition and circulate
Refill the tanks, establish material circulation and set component temperatures for the selected formulation.
Verify component delivery
Test the component discharge at the mixing head and calibrate flow, ratio and shot duration.
Mix and inject
Switch the component circuits to injection, impingement-mix the streams and complete the mechanical head-cleanout cycle.
¿Necesita una cotización de este equipo?
Solicitar presupuestoTechnical Parameters and Plant Interfaces
Reference configuration from the supplied technical agreement. Output is stated at a 1:1 ratio; final component selection and interface settings are confirmed for the project.
| Parámetro técnico | JHG-AFL-30 |
|---|---|
| Componentes | 2 components: polyol mixture and isocyanate |
| Rango de salida | 150–500 g/s combined output at 1:1; equivalent to 9–30 kg/min |
| Rango de relación de mezcla | 1:2–2:1 adjustable; confirm component order and calibration for the formulation |
| Referencia de precisión | Not specified as a separate ratio-accuracy value; verify component discharge during calibration |
| Alimentación eléctrica | 380 V, 50 Hz; approximately 28 kW total power in the reference configuration |
| Presión de trabajo | 10–20 MPa adjustable injection pressure |
| Capacidad de tanque/tolva | 2 × 280 L component tanks |
| Peso | Approximately 1.5 t, reference configuration |
| Dimensiones (L×An×Al) | 3.8 × 3.0 m reference footprint |
| Injection timer | 0.01–99.99 s stated setting range |
| Shot repeatability | ≤±1% for injection duration greater than 1 s |
| Metering pumps | Two A2VK-12 high-pressure metering pumps |
| Pump drives | 7.5 kW metering-pump drives; variable-frequency control and magnetic couplings |
| Mixing-head type | JHL-1410; hydraulically operated, mechanically self-cleaning impingement head |
| Hydraulic circuit | 10 L/min flow; 16–20 MPa stated system-pressure range |
| Hydraulic reservoir and accumulator | 80 L reservoir; 10 L accumulator |
| Material temperature conditioning | 22°C stated summer control point, ±2°C deviation; recipe setpoint agreed with material supplier |
| Temperature-control unit | 5 HP heating/cooling unit with two return-circuit heat exchangers |
| Aire comprimido | Dry, oil-free air; reference pressure 0.7 MPa and consumption 600 NL/min |
| Control hardware | Siemens PLC and 10-inch touchscreen HMI |
| Material refill | Two pneumatic diaphragm refill pumps; level indication with limit protection |
| Component filtration | 100 μm slit/scraper filters in the component circuits |
| Gas monitoring interface | Gas detector, audible alarm and linked extraction interface; settings agreed in the project scope |
| Tank pressure schedule | POL and ISO tank working-pressure limits, design pressures and relief-valve setpoints are specified separately in the approved vessel design and nameplate documentation, in accordance with the applicable pressure-vessel code |
Metering, Mixing and Control Functions
Independent High-Pressure Metering
A2VK-series component pumps, variable-frequency drives and magnetic couplings supply the polyol and isocyanate circuits.
Mechanical Mixing-Head Cleanout
The JHL-1410 hydraulic mixing head uses high-pressure impingement and mechanical cleanout. A balancer supports manual head-height adjustment.
High- and Low-Pressure Circulation
Coordinated circuit changeover controls material circulation and injection. Component discharge can be checked at the head.
Material Temperature Conditioning
Independent temperature sensors and return-line heat exchangers coordinate with the heating/cooling unit.
PLC and Touchscreen Operation
The HMI displays shot weight, component ratio, material levels, high/low component pressures and equipment alarms.
Monitoring and Extraction Interfaces
The supplied scope includes gas detection, an audible alarm and extraction actuation. Pressure and level monitoring support the defined equipment sequence.
Hablemos de la configuración de su equipo
Comparta su producto, materiales, utillaje y requisitos de producción para que podamos revisar el equipo y las interfaces para su proyecto.
Configuration Questions
At what ratio is the stated output measured?
Does this configuration include online cyclopentane premixing?
How is the mixing head cleaned?
Which plant interfaces are stated?
What gas-detection functions are included?
How are the tank pressure limits specified?
¿Listo para hablar de su proyecto?
Contacte con nuestro equipo